2YSL(St)CY

CORE

Copper

INSULATION

PE

TAPING

Polyester tape

SCREENING

Aluminium foil coverage 100%
Braiding of tinned copper wire coverage 75%

OUTER SHEATH

PVC Black or transparent

More info

APPLICATIONS

As motor connceting cable in machine tools, handling devices,production and processing tools band conveyors and industrial robots.Recommanded for EMC application.Outdoor use only with UV protection ( black color). Not for direct burial

CONDUCTOR CONSTRUCTION

Copper fine stranded class 5

TECHNICAL DATA

Nominal voltage Uo : 600 V
Nominal voltage U : 1000 V
Maximum permitted operating voltage in 3 phase systems: 1,7 kv
Test voltage : 3KV , 5 min
Insulation resistance : Min 20 Mohm x km

OTHER CHARACTERISTICS

Max permissible temperature at conductor :

  • In operation : +70° C
  • In short circuit : +150° C

Max operating temperature, fixed : -30 - +70° C
Temperature, moved, during installation : -5 - +70° C
Bending radius, fixed installation : 10Xd
Bending radius, moved application : 25Xd

CORE IDENTIFICATION

Colors according to VDE 0293( HD308)